Gateways
- Rockwell Automation
- Haupa
- Partex Marking Systems
- Steinel
- Disruptive Technologies
- ProSoft
- HMS
- Harting
- Festo
- Hager
- 10.00 Luftledningsmateriel og master
- 11.00 Kabelskabe
- 12.00 Kapslings- og tavlemateriel
- 13.00 Forskruningsmateriel
- 16.00 Målerrammer og gruppeafsætninger
- 17.00 Afbryder- og stikdåsemateriel
- 18.00 Industrimateriel
- 19.00 Jordings- og potentialudligningsmateriel
- 21.00 Forgreningsmateriel
- 22.00 Automatiske afbrydere/koblingsmateriel
- 23.00 Tids- og funktionsrelæer
- 24.00 Styrings- og funktionskomponenter
- 25.00 Sikringer
- 26.00 Intelligente bygningsinstallationer
- 27.00 Opmærkningsmateriel
- 28.00 Stikpropper og forlængerled
- 29.00 Højspændingsmateriel
- 30.00 Rør
- 32.00 Ledninger, stærkstrøm
- 35.00 Svagstrømskabler
- 36.00 Kabelkanaler og -lister
- 39.00 Befæstelsesmateriel
- 50.00 Glødelamper
- 60.00 Motorer, pumper, spændingsregulering og -overvågning m.m
- 61.00 Køl
- 62.00 Transformere
- 63.00 Strømforsyninger
- 67.00 Lysdæmpere og lysreguleringsudstyr
- 68.00 Materiel for transientbeskyttelse
- 78.00 Apparater for rumklima
- 82.00 Tele- og kommunikations- anlæg
- 84.00 Optiske transmissions- systemer
- 85.00 Overvågnings- og alarmanlæg
- 86.00 Data-installationsmateriel (ekskl. kabler)
- 87.00 Antenneanlæg
- 89.00 Elektroniksystemer
- 91.00 Elektronikkomponenter (passive)
- 92.00 Diverse komponenter, svagstrøm
- 94.00 Elementer, lygter og akkumulatorer
- 97.00 Værktøj
- 98.00 Instrumenter
- 99.00 Andre varer
Der opstod en fejl - prøv evt. igen.
Tak for din interesse. Vi vender tilbage!
CAN Open Router Module
EAN | 5703472634487 |
Type | A-CANOR/B |
Leverandør | Prosoft |
Varenr | 79.86.125.167 |
Tilgængelighed | Skaffevare |
Lagerstatus | Ikke på lager79.86.125.167 |
Leveringstid (dage) | 71 |
Pakningsstørrelse | 1 |
Salgsforpakning | 1 |
Enhed | Stk |
The A-CANOR/B CANopen® Router/B provides intelligent data routing between either EtherNet/IP , Modbus® RTU or Modbus TCP/IP® and the CANopen bus network. This allows the user to integrate CANopen devices into a Rockwell® Logix platform (e.g. ControlLogix® or CompactLogix ) or any Modbus device with minimal effort.
The module can be configured to be either a CANopen Master or Slave allowing the user to not only integrate CANopen devices into a Logix or Modbus system, but to also allow the user to use Logix, Modbus, or EtherNet/IP devices in an existing CANopen network (by using the CANopen Router B in Slave mode). In a Logix system the module can use Direct-To-Tag technology allowing CANopen devices to exchange data with a Logix controller without the need to write any ladder or application code in Studio 5000.
The module also provides a range of statistics to simplify the diagnostic process as well as a CANopen packet capture for remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CANopen operation and communication statistics, without the need for any additional software.
The module can be configured to be either a CANopen Master or Slave allowing the user to not only integrate CANopen devices into a Logix or Modbus system, but to also allow the user to use Logix, Modbus, or EtherNet/IP devices in an existing CANopen network (by using the CANopen Router B in Slave mode). In a Logix system the module can use Direct-To-Tag technology allowing CANopen devices to exchange data with a Logix controller without the need to write any ladder or application code in Studio 5000.
The module also provides a range of statistics to simplify the diagnostic process as well as a CANopen packet capture for remote diagnosis. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of CANopen operation and communication statistics, without the need for any additional software.